| Linde 2000 Perimeter Air Sampler Results | ||||||||||||||
| (Alpha Isotopic Analysis) | ||||||||||||||
| (Dose in mrem) | ||||||||||||||
| Sample Location | Jan | Feb | March | April | May | June | July | Aug | Sept | Oct | Nov | Dec | Dose for 6 Months | |
| Perimeter 1 | -- | -- | -- | -- | -- | -- | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | |
| Perimeter 2 | -- | -- | -- | -- | -- | -- | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | |
| Perimeter 3 | -- | -- | -- | -- | -- | -- | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | |
| Perimeter 4 | -- | -- | -- | -- | -- | -- | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | |
| Perimeter 5 | -- | -- | -- | -- | -- | -- | < 0.01 | < 0.01 | < 0.01 | 0.02 | < 0.01 | < 0.01 | 0.02 | |
| Perimeter 6 | -- | -- | -- | -- | -- | -- | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | 0.01 | 0.01 | |
| Perimeter 7 | -- | -- | -- | -- | -- | -- | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | |
| Perimeter 8 | -- | -- | -- | -- | -- | -- | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | 0.23 | 0.23 | |
| Perimeter 9 | -- | -- | -- | -- | -- | -- | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | |
| Perimeter 10 | -- | -- | -- | -- | -- | -- | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | < 0.01 | |
| -- | Pre-Operational Period, no dose calculations are applicable. | |||||||||||||
| Regulatory Guidance = 50 mrem/yr | (see 10 CFR 20 Appendix B) | |||||||||||||
| USACE Action Limit = 10 mrem/yr | (Suggested ALARA goal, 385-1-1, 3 September 1996) | |||||||||||||
| The natural background radioactivity measured at the Sheridan Park water tower was subtracted from the measured radioactivity | ||||||||||||||
| at each sampler prior to calculating dose. | ||||||||||||||