| Perimeter Air Sampler 6 (Northeast of Building 90 at Fence) | ||||||||
| Uranium-238 Alpha Spectroscopy Monthly Results | ||||||||
| Action limit for uranium-238 is 1.00E-12 µCi/ml (10 CFR 20 Appendix B Table 2). | ||||||||
| Pre-operational average uranium-238 baseline activity concentration is 8.0E-17 µCi/ml. | ||||||||
| Month | Hours | Lab Qualifier | Activity Concentration ± Uncertainty (µCi/mL) | |||||
| Jan-09 | 1010 | 3.2E-17 | ± | 1.5E-17 | ||||
| Feb-09 | 675 | 2.5E-17 | ± | 1.7E-17 | ||||
| Mar-09 | 667 | 5.3E-17 | ± | 2.6E-17 | ||||
| Apr-09 | 676 | 5.9E-17 | ± | 1.3E-17 | ||||
| May-09 | 842 | 3.8E-17 | ± | 2.0E-17 | ||||
| Jun-09 | 669 | 3.6E-17 | ± | 2.2E-17 | ||||
| Jul-09 | 841 | 4.7E-17 | ± | 1.2E-17 | ||||
| Aug-09 | 648 | 4.3E-17 | ± | 1.0E-17 | ||||
| Sep-09 | 676 | 3.4E-17 | ± | 2.0E-17 | ||||
| Oct-09 | 837 | 4.5E-17 | ± | 2.0E-17 | ||||
| Nov-09 | 672 | 6.1E-17 | ± | 2.8E-17 | ||||
| Dec-09 | 673 | 2.9E-17 | ± | 1.8E-17 | ||||
| Lab Qualifier Flags | ||||||||
| NR | No data reported for this radionuclide due to laboratory error or data found unacceptable during review | |||||||
| J | Nuclide identified, the associated numerical value is approximated | |||||||
| U | Nuclide not detected above the reported MDC or 2 sigma counting uncertainty | |||||||
| 0.00E+00 | Not detected in spectra | |||||||
| NA | Data not available at this time | |||||||